Rx Base Time

(Conventional Emergency Profiles, MDC)

HGDefinitionPort.jpg

Selects a number used by the radio to calculate the amount of time that the radio automatically de-keys and waits in the MDC Emergency Remote Monitor mode. This receive / wait time begins once the Tx Base Time has expired. This feature applies for the current Conventional Emergency Profile. Time is in seconds.

HGImportantNote.jpg

 

The radio uses the Rx Multiplier value (delivered to the radio within an Emergency Call Acknowledgement "Ack", or within a dispatcher sent Remote Monitor Command) multiplied by this Rx Base Time to determine the amount of Emergency Remote Monitor receive/wait time.

 

And if the Global Multiplier (delivered to the radio within an Emergency Call Acknowledgement "Ack", or within a dispatcher sent Remote Monitor Command) is set to "True", the calculated receive/wait time is doubled.

HGAccessedOnly.jpg

When the Emergency Type field is set to "Alarm and Call", and

when the radio is model / option capable.

HGSelections.jpg

Minimum

Maximum

Increments

10 sec

120 sec

10 sec

IconSmallNote.png

sec = seconds

GoArrow.jpg

Go to the MDC Page